Medium Voltage power cables for Renewables & Mobility

SIF/POL

Power cable reinforced with impregnated textile braiding

SIF_POL

  • 1,5kV (yellow), 3,7kV (brown), 6,6kV (grey), 13,8kV (black)
  • -55°C up to +180°C
  • Copper bare, tin-plated
  • Conductor class 5 acc. to IEC 60228
  • 1,5mm² - 400mm²
  • Semiconductive tape for cross sections ≥10mm²
  • Insulation silicone compound with reinforced varnished braid
  • Halogen-free acc. to IEC 60754-1
  • Flame propagation acc. to IEC 60332-1
  • Fire extinguishing acc. to IEC 60332-3
  • Fire resistance acc. to IEC 60331
  • Low smoke emission acc. to IEC 61034
  • Good resistance against UV and chemical fluids

SIF/POL UL

Power cable reinforced with impregnated texttile braiding acc. to UL & CSA

UL Style: 3640, 3988, 3641, 3989, 3642, 3990, 3643, 3991

  • 1,1kV (yellow), 3,3/4,2kV (brown), 6,9/7,2kV (grey), 13,8/15kV (black)
  • -55°C up to +150°C
  • Tin-plated
  • Conductor class 5 acc. to IEC 60228/UL758
  • AWG 16 (1,5 mm²) – 550Kcmil (300 mm²)
  • Semiconductive tape for cross sections ≥10mm²
  • Insulation silicone compound acc. to UL758
  • With reinforced varnished braid
  • Fire extinguishing acc. to IEC 60332-1, IEC 60332-3, VW-1, FT1, FT2
  • Fire resistance acc. to IEC 60331
  • Low smoke emission acc. to IEC 61034
  • Good resistance against ozone acc. to DIN EN 50305
  • Good resistance against UV and chemical fluids
  • CSA C22.2

SIF-C/POL

Shielded power cable reinforced with impregnated textile braiding

SIF C-POL

  • 1,5kV (yellow), 3,7kV (brown), 6,6kV (grey), 13,8kV (black)
  • -55°C up to +180°C
  • Copper bare, tin-plated
  • Conductor class 5 acc. to IEC 60228
  • 1,5mm² - 400mm²
  • Semiconductive tape for cross sections ≥10mm²
  • Insulation silicone compound
  • With reinforced varnished braid
  • Halogen-free acc. to IEC 60754-1
  • Flame propagation acc. to IEC 60332-1
  • Fire extinguishing acc. to IEC 60332-3
  • Fire resistance acc. to IEC 60331
  • Low smoke emission acc. to IEC 61034
  • Good resistance against UV and chemical fluids

FRNC-F

Single insulated power cable acc. to EN50382-2

FRNC-F

  • 1,8kV/3kV, 3,6kV/6kV
  • -40°C to +120°C (tinned or bare copper conductor)
  • -40°C to +150°C (bare copper conductor)
  • Conductor class 5 acc. to EN 50382-2 (optional class 6)
  • 2,5mm² - 400mm²
  • PET or semiconductive tape for cross sections ≥ 10mm²
  • Insulation silicone compound quality EI 111 acc. to EN50382-2
  • Halogen-free acc. to IEC 60754-1
  • Flame propagation single vertical cable acc. to IEC 60332-1-2
  • Flame propagation bunched cable acc. to IEC 60332-3
  • Railway applications acc. to EN 50382
  • Low smoke emission acc. to IEC 61034
  • Corrosiveness of combustion cable acc. to IEC 60754-2
  • Good resistance against UV

FRNC-FF

Double insulated power cable acc. to EN50382-2

FRNC-FF

  • 1,8kV/3kV , 3,6kV/6kV
  • -40°C to +120°C (tinned or bare copper conductor)
  • -40°C to +150°C (bare copper conductor)
  • Conductor class 5 acc. to EN 50382-2
  • 2,5mm² - 400mm²
  • PET tape for cross sections ≥ 10mm²
  • Insulation silicone compound quality EI 111 acc. to EN50382-2
  • Jacket silicone compound quality EM 107 acc. to EN50382-2
  • Halogen-free acc. to IEC 60754-1
  • Flame propagation single vertical cable acc. to IEC 60332-1-2
  • Flame propagation bunched cable acc. to IEC 60332-3
  • Railway applications acc. to EN 50382
  • Low smoke emission acc. to IEC 61034
  • Corrosiveness of combustion cable acc. to IEC 60754-2
  • Good resistance against UV

FRNC-FF S

Shielded insulated power cable acc. to EN50382-2

FRNC-FF S

  • 1,8kV/3kV , 3,6kV/6kV
  • -40°C to +120°C (tinned or bare copper conductor)
  • -40°C to +150°C (bare copper conductor)
  • Conductor class 5 acc. to EN 50382-2
  • 2,5mm² - 400mm²
  • PET tape for cross sections ≥ 10mm²
  • Shielded for excellent EMC performance
  • Insulation silicone compound quality EI 111 acc. to EN50382-2
  • Jacket silicone compound quality EM 107 acc. to EN50382-2
  • Halogen-free acc. to IEC 60754-1
  • Flame propagation single vertical cable acc. to IEC 60332-1-2
  • Flame propagation bunched cable acc. to IEC 60332-3
  • Railway applications acc. to EN 50382
  • Low smoke emission acc. to IEC 61034
  • Corrosiveness of combustion cable acc. to IEC 60754-2
  • Good resistance against UV

FRNC-FXZ

Power cable reinforced with glass braiding acc. to EN50382-2

FRNC-FXZ

FRNC-F XZ

  • 3,6kV/6kV
  • -40°C to +120°C (tinned or bare copper conductor)
  • -40°C to +150°C (bare copper conductor)
  • Conductor class 6 acc. to EN 50382-2
  • 50mm² - 185mm²
  • Semiconductive tape
  • Insulation silicone compound quality EI 111 acc. to EN50382-2
  • Textile braid (glass) for mechanical protection
  • Halogen-free acc. to IEC 60754-1
  • Flame propagation single vertical cable acc. to IEC 60332-1-2
  • Flame propagation bunched cable acc. to IEC 60332-3
  • Railway applications acc. to EN 50382
  • Low smoke emission acc. to IEC 61034
  • Corrosiveness of combustion cable acc. to IEC 60754-2
  • Good resistance against UV