Medium Voltage Power Cables for Renewables & Mobility
SIF/POL
Power Cable Reinforced with Impregnated Textile Braiding
- 1.5 kV (yellow), 3.7 kV (brown), 6.6 kV (grey), 13.8 kV (black)
- −55 °C up to +180 °C
- Copper bare, tin-plated
- Conductor class 5 acc. to IEC 60228
- 1.5 mm² − 400 mm²
- Semiconductive tape for cross sections ≥10 mm²
- Insulation silicone compound with reinforced varnished braid
- Halogen-free acc. to IEC 60754-1
- Flame propagation acc. to IEC 60332-1
- Fire extinguishing acc. to IEC 60332-3
- Fire resistance acc. to IEC 60331
- Low smoke emission acc. to IEC 61034
- Good resistance against UV and chemical fluids
SIF/POL UL
Power Cable Reinforced with Impregnated Textile Braiding acc. to UL & CSA
- 1.1 kV (yellow), 3.3/4.2 kV (brown), 6.9/7.2 kV (grey), 13.8/15 kV (black)
- −55 °C up to +150 °C
- Tin-plated
- Conductor class 5 acc. to IEC 60228/UL758
- AWG 16 (1.5 mm²) – 550 Kcmil (300 mm²)
- Semiconductive tape for cross sections ≥10 mm²
- Insulation silicone compound acc. to UL758
- With reinforced varnished braid
- Fire extinguishing acc. to IEC 60332-1, IEC 60332-3, VW-1, FT1, FT2
- Fire resistance acc. to IEC 60331
- Low smoke emission acc. to IEC 61034
- Good resistance against ozone acc. to DIN EN 50305
- Good resistance against UV and chemical fluids
- CSA C22.2
SIF-C/POL
Shielded Power Cable Reinforced with Impregnated Textile Braiding
- 1.5 kV (yellow), 3.7 kV (brown), 6.6 kV (grey), 13.8 kV (black)
- −55 °C up to +180 °C
- Copper bare, tin-plated
- Conductor class 5 acc. to IEC 60228
- 1.5 mm² − 400 mm²
- Semiconductive tape for cross sections ≥10 mm²
- Insulation silicone compound
- With reinforced varnished braid
- Halogen-free acc. to IEC 60754-1
- Flame propagation acc. to IEC 60332-1
- Fire extinguishing acc. to IEC 60332-3
- Fire resistance acc. to IEC 60331
- Low smoke emission acc. to IEC 61034
- Good resistance against UV and chemical fluids
FRNC-F
Single Insulated Power Cable acc. to EN50382-2
- 1.8 kV/3 kV, 3.6 kV/6 kV
- −40 °C to +120 °C (tinned or bare copper conductor)
- −40 °C to +150 °C (bare copper conductor)
- Conductor class 5 acc. to EN 50382-2 (optional class 6)
- 2.5 mm² − 400 mm²
- PET or semiconductive tape for cross sections ≥10 mm²
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV
FRNC-FF
Double Insulated Power Cable acc. to EN50382-2
- 1.8 kV/3 kV, 3.6 kV/6 kV
- −40 °C to +120 °C (tinned or bare copper conductor)
- −40 °C to +150 °C (bare copper conductor)
- Conductor class 5 acc. to EN 50382-2
- 2.5 mm² − 400 mm²
- PET tape for cross sections ≥10 mm²
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Jacket silicone compound quality EM 107 acc. to EN50382-2
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV
FRNC-FF S
Shielded Insulated Power Cable acc. to EN50382-2
- 1.8 kV/3 kV, 3.6 kV/6 kV
- −40 °C to +120 °C (tinned or bare copper conductor)
- −40 °C to +150 °C (bare copper conductor)
- Conductor class 5 acc. to EN 50382-2
- 2.5 mm² − 400 mm²
- PET tape for cross sections ≥10mm²
- Shielded for excellent EMC performance
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Jacket silicone compound quality EM 107 acc. to EN50382-2
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV
FRNC-FXZ
Power Cable Reinforced with Glass Braiding acc. to EN50382-2
- 3.6 kV/6 kV
- −40 °C to +120 °C (tinned or bare copper conductor)
- −40 °C to +150 °C (bare copper conductor)
- Conductor class 6 acc. to EN 50382-2
- 50 mm² − 185 mm²
- Semiconductive tape
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Textile braid (glass) for mechanical protection
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV