Medium Voltage power cables for Renewables & Mobility
SIF/POL
Power cable reinforced with impregnated textile braiding
- 1,5kV (yellow), 3,7kV (brown), 6,6kV (grey), 13,8kV (black)
- -55°C up to +180°C
- Copper bare, tin-plated
- Conductor class 5 acc. to IEC 60228
- 1,5mm² - 400mm²
- Semiconductive tape for cross sections ≥10mm²
- Insulation silicone compound with reinforced varnished braid
- Halogen-free acc. to IEC 60754-1
- Flame propagation acc. to IEC 60332-1
- Fire extinguishing acc. to IEC 60332-3
- Fire resistance acc. to IEC 60331
- Low smoke emission acc. to IEC 61034
- Good resistance against UV and chemical fluids
SIF/POL UL
Power cable reinforced with impregnated texttile braiding acc. to UL & CSA
- 1,1kV (yellow), 3,3/4,2kV (brown), 6,9/7,2kV (grey), 13,8/15kV (black)
- -55°C up to +150°C
- Tin-plated
- Conductor class 5 acc. to IEC 60228/UL758
- AWG 16 (1,5 mm²) – 550Kcmil (300 mm²)
- Semiconductive tape for cross sections ≥10mm²
- Insulation silicone compound acc. to UL758
- With reinforced varnished braid
- Fire extinguishing acc. to IEC 60332-1, IEC 60332-3, VW-1, FT1, FT2
- Fire resistance acc. to IEC 60331
- Low smoke emission acc. to IEC 61034
- Good resistance against ozone acc. to DIN EN 50305
- Good resistance against UV and chemical fluids
- CSA C22.2
SIF-C/POL
Shielded power cable reinforced with impregnated textile braiding
- 1,5kV (yellow), 3,7kV (brown), 6,6kV (grey), 13,8kV (black)
- -55°C up to +180°C
- Copper bare, tin-plated
- Conductor class 5 acc. to IEC 60228
- 1,5mm² - 400mm²
- Semiconductive tape for cross sections ≥10mm²
- Insulation silicone compound
- With reinforced varnished braid
- Halogen-free acc. to IEC 60754-1
- Flame propagation acc. to IEC 60332-1
- Fire extinguishing acc. to IEC 60332-3
- Fire resistance acc. to IEC 60331
- Low smoke emission acc. to IEC 61034
- Good resistance against UV and chemical fluids
FRNC-F
Single insulated power cable acc. to EN50382-2
- 1,8kV/3kV, 3,6kV/6kV
- -40°C to +120°C (tinned or bare copper conductor)
- -40°C to +150°C (bare copper conductor)
- Conductor class 5 acc. to EN 50382-2 (optional class 6)
- 2,5mm² - 400mm²
- PET or semiconductive tape for cross sections ≥ 10mm²
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV
FRNC-FF
Double insulated power cable acc. to EN50382-2
- 1,8kV/3kV , 3,6kV/6kV
- -40°C to +120°C (tinned or bare copper conductor)
- -40°C to +150°C (bare copper conductor)
- Conductor class 5 acc. to EN 50382-2
- 2,5mm² - 400mm²
- PET tape for cross sections ≥ 10mm²
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Jacket silicone compound quality EM 107 acc. to EN50382-2
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV
FRNC-FF S
Shielded insulated power cable acc. to EN50382-2
- 1,8kV/3kV , 3,6kV/6kV
- -40°C to +120°C (tinned or bare copper conductor)
- -40°C to +150°C (bare copper conductor)
- Conductor class 5 acc. to EN 50382-2
- 2,5mm² - 400mm²
- PET tape for cross sections ≥ 10mm²
- Shielded for excellent EMC performance
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Jacket silicone compound quality EM 107 acc. to EN50382-2
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV
FRNC-FXZ
Power cable reinforced with glass braiding acc. to EN50382-2
- 3,6kV/6kV
- -40°C to +120°C (tinned or bare copper conductor)
- -40°C to +150°C (bare copper conductor)
- Conductor class 6 acc. to EN 50382-2
- 50mm² - 185mm²
- Semiconductive tape
- Insulation silicone compound quality EI 111 acc. to EN50382-2
- Textile braid (glass) for mechanical protection
- Halogen-free acc. to IEC 60754-1
- Flame propagation single vertical cable acc. to IEC 60332-1-2
- Flame propagation bunched cable acc. to IEC 60332-3
- Railway applications acc. to EN 50382
- Low smoke emission acc. to IEC 61034
- Corrosiveness of combustion cable acc. to IEC 60754-2
- Good resistance against UV